Generator

A tree built at 3, measured to 2%, reads 2.957 on the informative band

The exponent recovered from 100 junctions of a tree built at exactly 3, against the relative error placed independently on the parent and on both daughters — half a per cent is a machined section under a microscope, one to two per cent is callipers on a clean branch, five is a branch that is not round, ten is a radius read off a photograph. Each line is a band of daughter ratio and the whiskers are the central 90% of 300 replicate samples. Every band is displaced downward at every error and never upward: at 2% the informative band read 2.957 and the informative band read 2.957. Below, the same rows with the displacement and the spread drawn as separate bars, because only one of them falls when more junctions are measured.
A tree built at 3, measured to 2%, reads 2.957 on the informative band. The exponent recovered from 100 junctions of a tree built at exactly 3, against the relative error placed independently on the parent and on both daughters — half a per cent is a machined section under a microscope, one to two per cent is callipers on a clean branch, five is a branch that is not round, ten is a radius read off a photograph. Each line is a band of daughter ratio and the whiskers are the central 90% of 300 replicate samples. Every band is displaced downward at every error and never upward: at 2% the informative band read 2.957 and the informative band read 2.957. Below, the same rows with the displacement and the spread drawn as separate bars, because only one of them falls when more junctions are measured.

Drawn at its defaults, in what an error in the radii costs. It takes no options at all, so every essay calling it gets this exact drawing.

Called by 4 essays

the blast radius of changing it

Branching and transport

The exponent an error moves

Every real measurement of a branch radius carries error and no synthetic tree does, so the question is what a symmetric error does to a fitted exponent. It does two things — a bias and a spread — and the bias runs downward at every error level and in every band, by an amount derivable from the daughter ratios alone.

Branching and transport

The fragile junctions are the informative ones

That is the obvious worry once the radii are uncertain, and it is false. Across the whole range of asymmetry a junction's contribution to the bias moves by a factor of 1.36 while its leverage moves by a factor of 308,352, so the junction that says nothing damages the answer as badly as the one that says everything — and a sample is spoiled by counting rather than by weight.

Branching and transport

The window that closes

The spread of a fitted branching exponent falls as the reciprocal root of the sample and its displacement does not fall at all, so there is a count past which every further junction buys confidence and no accuracy. Between three and five per cent of radius error the count arrives before the answer does, and no sample size both states a claim and contains the truth.

Branching and transport

Where three and two become one

Two trees, one built to obey Murray's law and one to obey Da Vinci's, are measured through the same fifty junctions with the same instrument. At twelve per cent of error on each radius the two answers overlap, and above twenty and a half the tree built at three measures lower than the tree built at two.

All 101 generators